The most advanced quartz technology dew point sensor available.
Pressure Dew Point (PDP) Range
-110°C to +0°C (-166°F to +32°F)
Gas Pressure Range
up to 17 bar (247 psi)
Dryer Types
Desiccant Dryers operating at -70ºC (-94°F) or lower
Gas Quality
No contaminates (ie no oil, particles or water vapour)
Accuracy
Dew point measurements:
• 0 to -80°C : ±2%
• -80 to -110°C : ±3%
Temperature measurements: ±0.5 °C
Pressure @ 23°C (optional): ±0.3% FS
Measure
Pressure dew point (PDP), Relative Humidity and Temperature
Optional – Pressure measurement (requires integrated pressure sensor).
Display
Optional 1.5” LCD Touch screen
Output
Modbus (RS485) and 4-20mA
Power requirement
10 to 30VDC, max 50 mA
Alarm
Alarm relay is optional – requires the touch screen display
Sensor Technology
Quartz sensor
Application
Manufacturing and industrial use
Temporary or permanent installation
Accessories
Extra M12 connectors and data cables are available.
The most advanced quartz technology dew point sensor available. Newly developed moisture sensitive materials provide superior signal sensitivity under ultra-low humidity conditions, providing long term, stability to measure pressure dew points down to -110°C (-166°F).
The innovative temperature compensation algorithm and multi-point temperature compensation calibration greatly improves the sensor’s temperature drift and ensures high-precision measurements over a wide temperature range. The precision sensor design compensates for contamination and aging, providing long-term, reliable, high-accuracy measurements.
The sensor is available with an in-built display or without a display. The display option includes an alarm relay and allows you to adjust the dew point settings (gas type, measurement units, modbus and 4-20mA settings, etc).
Best suited to
- Compressed air and gas systems to 4 Mpa (600psi)
- Desiccant dryers operating at -70ºC (-94°F) or lower
- Extremely dry dew points
- Very pure gases with no contamination (oil, particles, water vapour)
- Dew point range of -110°C to +0°C (-166°F to +32°F)
Key features of the Dew Point Sensor
- Next generation advanced quartz technology for extremely dry dew point conditions
- Dew Point Measurement Range: -110°C to +0°C (-166°F to +32°F)
- Accuracy +/- 3°C
- Fast response time
- Strong contamination resistance
- Modbus and 4-20mA outputs
- Measure:
- Pressure Dew Point (PDP)
- Gas temperature
- Relative humidity
- Pressure (optional)
- Optional in-built Display and alarm relay
Important
- This sensor is NOT recommended for refrigerant dryers.
- This sensor is NOT recommended for dew points above -20°C (-4°F)
- A minimum flow rate of > 1L/min is required for the sensor to read accurately
- The sensor must be installed in an upright position, after the dryer.
- Incorrect wiring or installation can damage the sensor and void the warranty. If you aren’t sure how to install or wire the sensor, please contact us. Full installation and wiring instructions are available in the User Manual.
Dew Point Sensor comes with:
- Measurement Chamber with adjustable silencer and removable Nitto type quick connect
(contact us for other measurement chamber options) - M12 connector (data cable optional)
- Calibration certificate
- User Manual
- 12 month warranty
Options for the Dew Point Sensor
- Integrated pressure sensor: 0 to 17 bar (247 psi)
- In-built Display
- 5 meter data cable
- Gas Types: Air, Argon, Carbon Dioxide, Carbon Monoxide, Helium, Hydrogen, Nitrogen, Oxygen
- Contact us for other measurement chambers or cable lengths.
Warranty & Calibration
12 month warranty
Calibration is recommended every 2 years (provided the sensor is not exposed to relative humidity above 85%).
Annual calibration is required if the sensor is exposed to relative humidity above 85%.
Accessories
Accessories such as mechanical and electrical fittings are available.
Other information
Part Numbers:
- Standard Dew Point Sensor (no display): DEQ010001, DEQ020001, DEQ110001, DEQ120001
- Dew Point Sensor with Display: DEQ011001, DEQ021001, DEQ111001, DEQ121001
| Weight | 1 kg |
|---|---|
| Dimensions | 23 × 16 × 10 cm |
Specifications
General
Technology |
Advanced Quartz Technology |
Dryer Types |
Compressed air and gas systems up to 4 MPa (600 PSI) Desiccant dryers operating at -70ºC (-94°F) or lower |
Gases |
Air, Argon, Carbon Dioxide, Carbon Monoxide, Helium, Hydrogen, Nitrogen, Oxygen |
Accuracy |
Dew Point:
Temperature:
Pressure: ±0.3% full scale (at 23°C), ±0.01 bar/10°C Note: the accuracy of the sensor is affected by on-site conditions. Contaminants such as oil, moisture, particles or other impurities can affect the calibration and accuracy of the sensor. |
Minimum Gas Flow Required |
> 1 litre per minute |
Measurement Ranges
Dew Point Measurement Range |
|
Pressure Measurement Range |
|
Gas Temperature Measurement Range |
|
Output
Outputs |
|
Modbus Output Signals |
|
Analogue Output Signals |
|
Alarm Relay |
Standard Dew Point Sensor (no display)
Dew Point Sensor with Display
|
Power Supply
Power |
Standard Dew Point Sensor (no display)
Dew Point Sensor with Display
|
Electrical Connection |
Standard Dew Point Sensor (no display)
Dew Point Sensor with Display
|
EMC |
According to IEC 61326-1 |
Other Information
Display |
Standard Dew Point Sensor (no display)
Dew Point Sensor with Display
|
Measurement Chamber |
Measurement Chamber with adjustable silencer and removable Nitto type quick connect Contact us for other measurement chamber options |
Ambient Temperature Range |
|
Relative Humidity |
0 to 95% RH |
Process Connection |
G1/2” thread Contact us for UNF process connection |
Dimensions |
Standard Dew Point Sensor (no display)
Dew Point Sensor with Display
|
Casing |
Standard Dew Point Sensor (no display)
Dew Point Sensor with Display
|
IP Rating |
IP65 |
Installation Type |
Permanent installation, or Temporary installation |
Calibration Frequency |
|
Warranty Period |
12 months |