Insertion type, thermal mass flow sensors. Good option where shutting down the system is difficult or impossible
Flow Range
0.1 to 250 Nm/s (0.3 to 820 ft/sec)
Gas Pressure Range
up to 50 bar (725 psi)
Gas Quality
Clean and dry compressed air and inert gases
Pipe Sizes
DN20 to DN600
Accuracy
Flow: ±1.5% reading, ±0.3% full scale
(high accuracy ±1% reading, ±0.3% full scale available on request)
Output
Modbus (RS485) and 4-20mA
Measure
Flow, Mass Flow, Consumption, Temperature
Power Requirement
18 to 30VDC / 5W@24VDC
Bi-directional
No
Measurement Principal
Mass Flow
Application
Manufacturing and industrial use
Temporary or permanent installation
Accessories
Our Flow Meters have BSP thread. If your fittings are NPT thread, you will need a BSP to NPT adapter. The transparent Flow Meter Enclosure will protect the flow meter head from liquids and other damage. Extra M12 connectors and data cables are available.
Thermal mass flow meters are perfectly suited for measuring clean, dry compressed air and inert gases, where accuracy on smaller pipe sizing is important. Mitra Air offers two types of thermal mass flow meters – insertion flow meter and inline (or in-line) flow meter.
Insertion flow meters
- Insertion flow sensors are inserted into the pipe through a valve. They can be inserted under pressure so you don’t need to turn off your compressed air system during installation.
- Suitable for pipes from DN20 to DN600
- Insertion flow meters are best used for permanent and temporary installations.
Inline Flow Meters
- Inline flow sensors include a section of pipe as part of the flow meter. You will need to turn off compressed air and cut a section of pipe out to install the inline flow meter.
- For information on Inline Flow Meters, refer to Inline Flow Meter page.
Both of thermal mass flow meters (inline and insertion style) have a streamlined sensor tip which ensures minimal impact on gas flow while maintaining accuracy over a wide flow range.
Features of Thermal Mass Flow Meter
- Insertion type sensor
- Thermal mass technology
- High speed flow range: 0.1 to 250 Nm/s
- Integrated temperature sensor
- Easy to insert and remove through 1/2″ valve, even when under pressure
- Modbus RTU and 4 to 20 mA + Pulse outputs
- Low pressure drop
- 2.8″ ultra-wide viewing angle LCD touch screen
- Data logging with up to 10,000,000 recording points
- Suitable for pipes from DN20 – DN600 provided minimum velocity is maintained
- Accuracy of +/-1.5% reading, +/-0.3% full scale
- Ask us about high accuracy sensors (+/-1% reading, +/-0.3% full scale)
- Measures standard flow, mass flow, consumption and temperature
- 12 month warranty
- No moving parts, low pressure drop
- Full electrical isolation to filter out disturbances
- Stable signals
- Vibration resistant
Thermal Mass Meter comes with:
- M12 connector (data cable optional)
- Calibration certificate
- User Manual
- 12 month warranty
Thermal Mass Flow Meter Options
- Two shaft length options: 250 mm (9.8″) or 400 mm (15.7″)
- Multiple gas options: Air, Argon, Carbon Dioxide, Helium, Hydrogen, Natural Gas, Nitrogen, Nitrous Oxide, Oxygen
Important
- The sensor must be installed (i) in dry gas, (ii) at 90° to the pipe and (iii) away from bends, edges, seams, changes in pipe size and other obstructions,
- Incorrect wiring or installation can give false readings, damage the sensor and void the warranty. If you aren’t sure how to install or wire the sensor, please contact us. Full installation and wiring instructions are available in the User Manual.
Warranty & Calibration
12 month warranty
Calibration is recommended every 2 years (provided the sensor is not exposed to relative humidity above 85%).
Annual calibration is required if the sensor is exposed to relative humidity above 85%.
Accessories
Accessories such as mechanical and electrical fittings are available.
Other Information
Part Numbers: FLT100001, FLT200001, FLT100011, FLT200011, FLT100101, FLT200101, FLT100111, FLT200111, FLT110001, FLT210001, FLT110011, FLT210011, FLT110101, FLT210101, FLT110111, FLT210111
| Weight | 1.75 kg |
|---|---|
| Dimensions | 69 × 21 × 17 cm |
Specificiations
General
Technology |
Thermal mass, Insertion design |
Gases |
Air, Argon, Carbon Dioxide, Helium, Hydrogen, Natural Gas, Nitrogen, Nitrous Oxide, Oxygen |
Gas Quality |
Clean and dry gases |
Accuracy |
Standard accuracy: ±(1.5% reading + 0.3% full scale)
High level accuracy (optional): ±(1% reading + 0.3% full scale) Note: the accuracy of the sensor is affected by on-site conditions. Contaminants such as oil, high humidity or other impurities can affect the calibration and accuracy of the sensor. |
Minimum Gas Flow Required |
|
Measurement Ranges
Flow Measurement Range |
|
Pressure Measurement Range |
|
Gas Temperature Measurement Range |
|
Output
Outputs |
|
Modbus Output Signals |
|
Analogue Output Signals |
One measurement only |
Power Supply
Power |
18 to 30VDC / 5W@24VDC |
Electrical Connection |
2 x 5 pin M12, female |
EMC |
According to IEC 61326-1 |
Data Logger and Display
Data Logger |
10,000,000 samples
> 20 samples / second |
Display |
2.8” LCD with touch panel |
Other Information
Shaft Lengths |
|
Pipe Sizes |
DN20 to DN600 |
Process Connection |
ISO G1/2″ thread |
Ambient Temperature Range |
|
Installation Type |
Permanent installation, or Temporary installation |
Calibration Frequency |
|
Warranty Period |
12 months |