Pitot Tube flow meter. Ideally suited to wet, dirty and high velocity compressed air and inert gas systems that contain some level of contamination.
Flow Range
5 – 300 Nm/s (17 to 984 ft/s)
Gas Pressure Range
up to 17 bar (247 psi)
Gas Quality
Wet, dirty and high velocity compressed air and inert gas systems
Pipe Sizes
DN25 to DN600
Accuracy
Flow: ±1.5% reading, ±0.3% full scale
Pressure: ±0.5% full scale
Output
Modbus (RS485) and 4-20mA
Measure
Flow, Consumption, Pressure, Temperature
Power Requirement
18 to 30VDC / 6.5W@24VDC
Bi-directional
Optional
Measurement Principal
Volumetric
Application
Manufacturing and industrial use
Temporary or permanent installation
Accessories
Our Flow Meters have BSP thread. If your fittings are NPT thread, you will need a BSP to NPT adapter. The transparent Flow Meter Enclosure will protect the flow meter head from liquids and other damage. Extra M12 connectors and data cables are available.
Pitot tube flow meters are ideally suited to wet, dirty and high velocity compressed air and gas systems that contain some level of contamination. This makes a pitot tube flow meter ideal for measuring flow, temperature and pressure near the outlet of compressors and other difficult environments.
Pitot tube flow meters have no moving parts, a low pressure drop and are vibration proof. The integrated pressure and temperature sensors give real-time monitoring of fluid pressure and temperature. The sensor has an extremely sensitive differential pressure measurement that allows pitot tube flow meters to be used over a wide flow range, whilst the patented anti-condensation technology ensures the sensor can be used under 100% saturated conditions. The flow meter can be easily installed under pressure through a 1/2″ ball valve.
Innovative online auto-calibration technology compensates for temperature and pressure changes, enabling the pitot tube flow meter to perform stable accurate measurements for years to come.
Best suited to
- Wet and dirty gases
- High velocity gases (5 to 300 Nm/s or 17 to 984 ft/s)
- Note: below minimum velocity flow, the meter read will be zero. If your gas flow rate is less than 5 Nm/s (17 ft/s) and your gas is clean and dry, we recommend a Thermal Mass Flow Sensor.
- Permanent or temporary installation
Features of Pitot Tube Flow Meters
- Insertion type sensor
- Ideal for wet and dirty gases
- Flow range of 5 – 300 Nm/s (17 to 984 ft/s)
- Note: below minimum velocity flow, the meter read will be zero. If your gas flow rate is less than 5 Nm/s (17 ft/s) and your gas is clean and dry, we recommend a Thermal Mass Flow Sensor.
- Accuracy of +/-1.5% reading, +/-0.3% full scale
- Integrated display with touch panel and data logging
- Two output types as standard:
- Digital – Modbus RTU and
- Analog – 4-20 mA + Pulse
- Suitable for pipes from DN25-DN600 provided minimum velocity (min 5 Nm/s or 17 ft/s) is maintained
- Easy to insert and remove through 1/2″ valve, even when under pressure
- ISO G1/2″ screw connection
- Full electrical isolation to filter out disturbances
- No moving parts, low pressure drop
- Stable signals, vibration resistant
- Extremely sensitive differential pressure sensor
- Integrated pressure and temperature sensors for real-time monitoring of fluid pressure and temperature
- Innovative online auto-calibration function to compensate the temperature and pressure change
- Patented anti condensation technology
- Anti-particulate pollution, oil vapour and most chemicals
Important
- You need to maintain a minimum flow velocity of 5 Nm/s (17 ft/s) for the pitot tube to work correctly. Below this minimum velocity, the flow meter reading will be zero.
- Flow meters must be installed away from bends, edges, seams, changes in pipe size and other obstructions
- Incorrect wiring or installation can give false readings, damage the sensor and void the warranty. If you aren’t sure how to install or wire the sensor, please contact us. Full installation and wiring instructions are available in the User Manual.
Pitot Tube Flow Meter comes with:
- M12 connector (data cable optional)
- Calibration certificate
- User Manual
- 12 month warranty
Pitot Tube Flow Meter Options
- Two shaft length options: 250 mm (9.8″) or 400 mm (15.7″)
- Multiple gas options: Air, Argon, Carbon Dioxide, Helium, Hydrogen, Natural Gas, Nitrogen, Nitrous Oxide and Oxygen
Warranty & Calibration
12 month warranty
Calibration is recommended every 2 years (provided the sensor is not exposed to relative humidity above 85%).
Annual calibration is required if the sensor is exposed to relative humidity above 85%.
Accessories
Accessories such as mechanical and electrical fittings are available.
Other Information
Part Numbers: FLP100001, FLP200001, FLP110001, FLP210001, FLP110011, FLP210011
| Weight | 2.5 kg |
|---|---|
| Dimensions | 69.5 × 21 × 17 cm |
Specifications
General
Technology |
Anti-condensation |
Gases |
Air, Argon, Carbon Dioxide, Helium, Hydrogen, Natural Gas, Nitrogen, Nitrous Oxide, Oxygen |
Gas Quality |
|
Accuracy |
Flow: ±(1.5% reading + 0.3% full scale)
Pressure: ±0.5% full scale Temperature: ±0.5°C Note: the accuracy of the sensor is affected by on-site conditions. Contaminants such as oil, high humidity or other impurities can affect the calibration and accuracy of the sensor. |
Minimum Gas Flow Required |
Note: below this the Pitot Tube Flow Meter will read zero (“0”) |
Measurement Ranges
Flow Measurement Range |
|
Pressure Measurement Range |
|
Gas Temperature Measurement Range |
|
Output
Outputs |
|
Modbus Output Signals |
|
Analogue Output Signals |
One measurement only |
Power Supply
Power |
|
Electrical Connection |
2 x 5 pin M12, female |
EMC |
According to IEC 61326-1 |
Data Logger and Display
Data Logger |
10,000,000 samples
> 20 samples / second |
Display |
2.8” LCD with touch panel |
Other Information
Pipe Sizes |
DN25 to DN300 |
Shaft Length |
|
Process Connection |
ISO G1/2″ thread |
Ambient Temperature Range |
|
Installation Type |
|
Calibration Frequency |
|
Warranty Period |
12 months |