The Vortex flow meter is perfectly suited for measuring the volume of gases and steam using the Karman vortex principle.
Flow Range
1.5 to 300 Nm/sec (5 to 931 ft/sec)
Gas Pressure Range
up to 63 bar (913 psi)
Gas Quality
Wet, dirty compressed air, steam and inert gas systems
Pipe Sizes
DN15 to DN300
Accuracy
Flow: ±1.5% reading, ±0.3% full scale
Output
Modbus (RS485)
Measure
Flow, Pressure, Temperature
Power Requirement
18 to 30VDC / 10W@24V
Bi-directional
No
Measurement Principal
Volumetric
Application
Manufacturing and industrial use
Temporary or permanent installation
The Vortex flow meter is perfectly suited for measuring flow and consumption of inert gases and steam in both clean or dirty gas environments. With no moving parts, these sensors are both durable and easy to maintain.
The design of this meter allows for precise measurements of most gases and steam no matter how heavily contaminated. With built-in pressure and temperature sensors, all parameters of your gas or steam system are monitored in one unit, saving you install and maintenance costs. The integrated display allows installers to set the flow meter without any additional equipment and for users to read the information in real time right at the meter.
Pipe sections are available from DN15 to DN300.
Features of Vortex Flow Meters
- Inline type sensor
- Measurement range: 1.5 to 300 Nm/s (5 to 931 ft/sec)
- Integrated 2” touch screen display
- Measures flow, pressure, and temperature
- Ultra-high sensitivity dual vortex probe
- Turndown ratio of 1:53 goes beyond traditional Vortex flowmeters
- Full digital signal processing for higher precision and better stability
- Accuracy of ±1.5% reading, ±0.3% full scale (high accuracy of +/-1% reading, +/-0.3% full scale, available upon request)
- Integrated pressure and temperature sensors
- No moving parts
- Suitable for pipes from DN15 – DN300 provided minimum velocity is maintained
- Modbus RTU and 4 to 20 mA + Pulse outputs
- 12 month warranty
- Full electrical isolation to filter out disturbances
- Stable signals
- Vibration resistant
- All-welded construction for corrosion resistance, high pressure and high temperature resistance
Vortex Flow Meter comes with
- Calibration certificate
- User Manual
- 12 month warranty
Vortex Flow Meter Options
- Pressure: 1.6 MPa (16 bar) or 6.3 MPa (63 bar)
- Pipe Section: DN15, DN20, DN25, DN32, DN40, DN50, DN65, DN80, DN100, DN125, DN150, DN200, DN250, DN300
- Medium: Gas or Steam
- Gas Types: Air, Argon, Carbon Dioxide, Carbon Monoxide, Helium, Hydrogen, Natural Gas, Nitrogen, Nitrous Oxide, Oxygen
Contact us for other pipe section sizes.
Important
- Incorrect wiring or installation can give false readings, damage the sensor and void the warranty. If you aren’t sure how to install or wire the sensor, please contact us. Full installation and wiring instructions are available in the User Manual.
Warranty
12 month warranty
Specificiations
General
Technology |
Vortex, Inline design |
Medium |
Inert Gas, Steam, Liquids |
Gas Types |
Air, Argon, Carbon Dioxide, Carbon Monoxide, Helium, Hydrogen, Natural Gas, Nitrogen, Nitrous Oxide, Oxygen, Sulfur hexafluoride (SF6) |
Accuracy |
Flow: ±(1.5% reading + 0.3% full scale)
Note: the accuracy of the sensor is affected by on-site conditions. Contaminants such as oil, high humidity or other impurities can affect the calibration and accuracy of the sensor. |
Minimum Gas Flow Required |
|
Measurement Ranges
Flow Measurement Range |
|
Pressure Measurement Range |
|
Temperature Measurement Range |
|
Output
Outputs |
Digital: RS485 Modbus / RTU |
Modbus Output Signals |
|
Power Supply
Power |
18 to 30VDC / 10W@24V |
EMC |
According to IEC 61326-1 |
Data Logger and Display
Display |
2.0” LCD with touch panel |
Other Information
Pipe Sizes |
DN15 to DN300 |
Process Connection |
Flange |
Ambient Temperature Range |
|
Installation Type |
Permanent installation, or Temporary installation |
Calibration Frequency |
|
Warranty Period |